Order code · rod type · Ø10.2 mm, M18×1.5 thread
BAF-B series - SSI · 200 mm
BAF-S562-M0200-B-S32 (BAF-B series - SSI) is a rod-type magnetostrictive linear position sensor with a measuring length of 200 mm, fitted with connector M16x0.75, 8 pin.
Mechanical design: rod type · Ø10.2 mm, M18×1.5 thread.
It is a TIBAFF own brand product; the reference model BTL7-S562-M0200-B-S32 (Balluff model) is used for specification reference only.
| supply voltage | 10…30 V DC |
|---|---|
| nominal length | 200 mm |
| rod version | metric mounting thread M18×1.5, O-ring sealed, rod diameter 10.2 mm |
| Interface | RS422 / RS485 |
| Protocol | SSI (synchronous serial interface) |
| Data format | 25 bit |
| Encoding | Binary code |
| Counting direction | increasing (Up) |
| Electrical connection | connector M16x0.75, 8 pin |
| Measuring length | 200 mm |
| Mechanical specifications | rod type Ø10.2 mm, metric mounting thread M18×1.5, O-ring sealed; zero point = 30 mm; pressure resistance 600 bar |
| Supply voltage Ub | 10 - 30 VDC |
| Resolution (LSB) | 5 µm |
| Synchronous / asynchronous | Asynchronous operation |
| Stabilization time (tm) | 30 µs |
| Clock frequency | 10 kHz … 1 MHz |
| Output impedance | > 120 Ω |
| Short-circuit protection | Yes (output can be tied to ground or to the supply voltage, max. 7 V) |
| Repeatability | < ±5 µm |
| Linearity deviation | ± 50 µm |
| Max. measuring frequency | 4000 Hz |
| Ambient temperature | -40 … 85 °C |
| Degree of protection (IP) | IP67 |
| max. current consumption at 24 V DC | 150 mA |
| protective tube diameter | 10.2 mm |
| mounting length (from the contact surface) | 290 mm |
| Tightening torque, max. | 100 N·m |
| max. pressure resistance | 600 bar |
| tightening | threaded flange M18x1.5 |
| zero point | 30.0 mm |
| housing material | aluminium, anodized; protective tube stainless steel 1.4571 |
| sealing material | FKM |
| storage temperature | -40 … 100 °C |
| Temperature coefficient, typical | ≤ 30 ppm/K (at 50 % of 500 mm nominal length) |
| relative air humidity | ≤ 90 %, non-condensing |
| Dielectric strength (GND - housing) | 500 V AC |
| electrical insulation | No |
| Overvoltage protection | Ub max. 36 V |
| EMC test | EN 61000-4-2 / -3 / -4 / -5 / -6 / -8; EN 60068-2-6 (20 g, 10…2000 Hz) |
| conformity | CE / UKCA / cULus / DNV / WEEE |
Price and lead time on request. Other measuring lengths in the same series can be customised — we reply with a selection recommendation within one business day.